MOXA TN-5916 Series
Product is End of Life : 2022-12-31
EN 50155 16-port NAT router
produits de remplacement
Moxa TN-4900 Series
- Routing functionality to divide a large network into hierarchical subnets and allow data and information to communicate across networks
- NAT makes IP management easier, since end devices in different carriages can use the same IP addresses
- Leading EN 50155-compliant Ethernet router for rolling stock applications
- Turbo Ring and RSTP/STP for network redundancy
- IGMP V1/V2 snooping for filtering multicast traffic
- IEEE 802.1Q VLAN to ease network planning
- QoS (IEEE 802.1p/1Q and TOS/DiffServ) to improve reliability
- IEEE 802.3ad for Static Port Trunking
- SNMPv3, HTTPS, and SSH to enhance network security
- SNMP v1/v2c/v3 for different levels of network management
- Port mirroring for online debugging
- Automatic warning by exception through email and relay output
- Line-swap fast recovery
- Automatic recovery of connected device’s IP addresses
- LLDP for automatic topology discovery in network management software
- Configurable by web browser, Telnet/serial console, and CLI Windows utility
- Panel mounting or DIN-rail mounting installation capability
The ToughNet TN-5916, designed for rolling stock backbone networks, is a high performance M12 router with four bypass relay backbone ports. It supports NAT and routing functionality to facilitate the deployment of applications across networks. The TN-5916 router uses M12 and other circular connectors to ensure tight, robust connections that guarantee reliability against environmental disturbances, such as vibration and shock. The TN-5916 router provides a wide power input range of 24 to 110 VDC. The TN-5916 operates in an extended operating temperature range of -40 to 75°C and is compliant with EN 50155/50121-4 requirements, making the router suitable for a variety of industrial applications.
Technology
- Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.3ad for Static Port Trunking
Software Features
- Management
SNMP v1/v2c/v3, Account Management, Telnet, Console - CLI, DHCP Server, LLDP, Port Mirror, Syslog, TFTP, SMTP Client, RARP, HTTP, HTTPS, SNMP inform, Flow Control, Back pressure flow control
Filter
802.1Q VLAN, IGMPv1/v2, Static Multicast
Redundancy Protocols
STP/RSTP, Turbo Ring v2, Static Port Trunk
Security
Management Interface Control (TCP/UDP port blocking), Trusted Access Control
Time Management
SNTP, NTP Server/Client
Routing Redundancy
VRRP
NAT
N-1 NAT, 1-1 NAT, Port Forwarding
Router Properties
- Priority Queues
4
Max. Number of VLANs
16
VLAN ID Range
VID 1 to 4094
IGMP Groups
256
Interface
- Fast Ethernet
Front cabling, M12 D-coded 4-pin female connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection, with 4 bypass relays on backbone ports
Console Port
M12 A-coded 5-pin male connector
Alarm Contact
2 relay outputs in one M12 A-coded 5-pin male connector with current carrying capacity of 1 A @ 30 VDC
Power Requirements
- Input Voltage
24/36/48/72/96/110 VDC
Operating Voltage
16.8 to 137.5 VDC
Input Current
0.85 A @ 24 VDC; 0.17 A @110 VDC
Overload Current Protection
Present
Connection
M23 connector
Reverse Polarity Protection
Present
Physical Characteristics
- Housing
Aluminium alloy
IP Rating
IP54 protection (optional protective caps available for unused ports)
Dimensions
250 x 175.8 x 116.3 mm (9.84 x 6.92 x 4.58 in)
Weight
4030 g (8.88 lb)
Installation
Panel mounting, DIN-rail mounting (with optional kit)
Environmental Limits
- Operating Temperature
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Altitude
2,000 m
Standards and Certifications
- Safety
UL/cUL 508, EN 60950-1 (LVD)
EMC
EN 55022, EN 55024
EMI
CISPR 22, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic
EN 50155 (essential compliance*), EN 50121-4, EN 45545-2
* Moxa defines “essential compliance” to include those EN 50155 requirements that make products more suitable for rolling stock railway applications.
Shock
EN 50155, EN/IEC 61373
Freefall
IEC 60068-2-32
Vibration
EN 50155, EN/IEC 61373
MTBF (mean time between failures)
- Time
556,025 hrs
Standard
Telcordia SR332
Ordering Information
Available Modules | |
TN-5916-WV-T | NAT router with 16 10/100BaseT(X) ports, and 4 of 10/100BaseT(X) ports with bypass relay function, dual redundant power inputs (24 - 110 VDC), -40 to 75°C operating temperature |
TN-5916-WV-CT-T | NAT router with 16 10/100BaseT(X) M12 ports and 4 of 10/100BaseT(X) ports with bypass relay function, dual power inputs ( 24 to 110 VDC), -40 to 75°C operating temperature, conformal coating model |
Clients qui ont dájà consulté cet article ont également vu