MOXA MGate MB3170 / MB3270

1 and 2-port advanced serial-to-Ethernet Modbus gateways

MOXA MGate MB3170 / MB3270
2641_24995.png
2641_24997.png
2641_24998.png
2641_33377.jpg
2641_33378.jpg
2641_33379.jpg
2641_33380.jpg
  • Les caractéristiquesLes caractéristiques
  • PrésentationPrésentation
  • Plus d'informationPlus d'information
  • PDFPDF
  • Supports Auto Device Routing for easy configuration
  • Supports route by TCP port or IP address for flexible deployment
  • Connects up to 32 Modbus TCP servers
  • Connects up to 31 or 62 Modbus RTU/ASCII slaves
  • Accessed by up to 32 Modbus TCP clients (retains 32 Modbus requests for each Master)
  • Supports Modbus serial master to Modbus serial slave communications
  • Built-in Ethernet cascading for easy wiring
  • 10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC/ST connector)
  • Emergency request tunnels ensure QoS control
  • Embedded Modbus traffic monitoring for easy troubleshooting
  • Serial port with 2 kV isolation protection (for “-I” models)
  • -40 to 75°C wide operating temperature models available
  • Supports redundant dual DC power inputs and 1 relay output
The MGate MB3170 and MB3270 are 1 and 2-port Modbus gateways, respectively, that convert between Modbus TCP, ASCII, and RTU communications protocols. The gateways provide both serial-to-Ethernet communication and serial (master) to serial (slave) communications. In addition, the gateways support simultaneously connecting serial and Ethernet masters with serial Modbus devices. The MGate MB3170 and MB3270 Series gateways can be accessed by up to 32 TCP master/clients or connect to up to 32 TCP slave/servers. Routing through the serial ports can be controlled by IP address, TCP port number, or ID mapping. A featured priority control function allows urgent commands to obtain an immediate response. All models are rugged, DIN-rail mountable, and offer optional built-in optical isolation for serial signals.


Integrate TCP Masters without Altering the Modbus RTU/ASCII Network or Software

The MB3270 can integrate Modbus TCP with Modbus RTU/ASCII, without modifying the existing Modbus RTU/ASCII architecture or software. With the serial redirector function, a serial master can maintain direct access to serial slave devices through a specially mapped serial port. This allows the serial and TCP masters to access serial slaves simultaneously.


Optical Fiber for Ethernet Communication

The MGate MB3170 Series includes 100BaseFX fiber models that support transmission distances up to 4 km for multi-mode models, and up to 40 km for single-mode models. Optical fiber is well-suited for industrial applications because it is immune to electromagnetic noise and interference. For environments that experience high ground loop voltages, fiber provides the best isolation protection, and because there is no danger of sparking, optical fiber is safer than copper wire to use in hazardous environments.


Auto-Device Routing for Easy Configuration (Patent Pending)

Moxa’s Auto-Device Routing function helps eliminate many of the problems and inconveniences encountered by engineers who need to configure large numbers of Modbus devices. A single mouse click is all that’s required to set up a slave ID routing table and configure Modbus gateways to automatically detect Modbus requests from a supervisory control and data acquisition (SCADA) system. By removing the need to manually create the slave ID routing table, the Auto-Device Routing function saves engineers significant time and cost.


Priority Control for Urgent Commands (Patented)

As Modbus networks increase in size and complexity, the lag time between commands and responses becomes a major concern. Advanced models of the MB3000 Series provide a priority control function for urgent commands, allowing users to force certain commands to get an immediate response. Depending on your system’s requirements, different methods are available to define which commands receive priority.

ProdGrafik
Specifications

    Ethernet Interface

      10/100BaseT(X) Ports (RJ45 connector)
      2 (1 IP, Ethernet cascade)
      Auto MDI/MDI-X connection

      Magnetic Isolation Protection
      1.5 kV (built-in)

      Optical Fiber
        100BaseFX
      Multi-Mode Single-Mode
      Fiber Cable Type OM1 50/125 μm G.652
      800 MHz x km
      Typical Distance 4 km 5 km 40 km
      Wavelength Typical (nm) 1300 1310
      TX Range (nm) 1260 to 1360 1280 to 1340
      RX Range (nm) 1100 to 1600 1100 to 1600
      Optical Power TX Range (dBm) -10 to -20 0 to -5
      RX Range (dBm) -3 to -32 -3 to -34
      Link Budget (dB) 12 29
      Dispersion Penalty (dB) 3 1


      Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
      Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).



    Ethernet Software Features

      Industrial Protocols
      Modbus TCP Client (Master), Modbus TCP Server (Slave)

      Configuration Options
      Web Console (HTTP/HTTPS), Device Search Utility (DSU), MGate Manager, MCC Tool,Telnet Console

      Management
      ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client

      MIB
      RFC1213, RFC1317

      Time Management
      NTP Client



    Security Functions

      Authentication
      Local database

      Encryption
      HTTPS, AES-128, AES-256, SHA-256

      Security Protocols
      SNMPv3
      HTTPS (TLS 1.2)



    Serial Interface

      No. of Ports
      MGate MB3170 Series: 1
      MGate MB3270 Series: 2

      Connector
      MGate MB3170/MB3170I: DB9 male for RS-232 and terminal block for RS-422/485
      MGate MB3270/MB3270I: 2 x DB9 male

      Serial Standards
      RS-232/422/485 (software selectable)

      Baudrate
      50 bps to 921.6 kbps

      Data Bits
      7, 8

      Parity
      None, Even, Odd, Space, Mark

      Stop Bits
      1, 2

      Flow Control
      DTR/DSR, RTS Toggle (RS-232 only), RTS/CTS

      RS-485 Data Direction Control
      ADDC® (automatic data direction control)

      Pull High/Low Resistor for RS-485
      1 kilo-ohm, 150 kilo-ohms

      Terminator for RS-485
      120 ohms

      Isolation
      2 kV (I models)



    Serial Signals

      RS-232
      TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

      RS-422
      Tx+, Tx-, Rx+, Rx-, GND

      RS-485-2w
      Data+, Data-, GND

      RS-485-4w
      Tx+, Tx-, Rx+, Rx-, GND



    Serial Software Features

      Industrial Protocols
      Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave



    Modbus (Transparent)

      Max. No. of Client Connections
      32

      Max. No. of Server Connections
      32



    Power Parameters

      Input Current
      MGate MB3170/MB3270: 435 mA @ 12 VDC
      MGate MB3170I/MB3170-S-SC/MB3170I-M-SC/MB3170I-S-SC: 555 mA @ 12 VDC
      MGate MB3270I/MB3170-M-SC/MB3170-M-ST: 510 mA @ 12 VDC

      Power Connector
      7-pin terminal block



    Relays

      Contact Current Rating
      Resistive load: 1 A @ 30 VDC



    Physical Characteristics

      Housing
      Plastic

      IP Rating
      IP30

      Dimensions (with ears)
      29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)

      Dimensions (without ears)
      29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)

      Weight
      MGate MB3170 Series: 360 g (0.79 lb)
      MGate MB3270 Series: 380 g (0.84 lb)



    Environmental Limits

      Operating Temperature
      Standard Models : 0 to 60°C (32 to 140°F)
      Wide Temp. Models: -40 to 75°C (-40 to 167°F)

      Storage Temperature (package included)
      -40 to 85°C (-40 to 185°F)

      Ambient Relative Humidity
      5 to 95% (non-condensing)



    Standards and Certifications

      EMC
      EN 55032/24

      EMI
      CISPR 32, FCC Part 15B Class A

      EMS
      IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
      IEC 61000-4-11

      Hazardous Locations
      ATEX, Class I Division 2, IECEx

      Maritime
      DNV-GL

      Freefall
      IEC 60068-2-32

      Shock
      IEC 60068-2-27

      Vibration
      IEC 60068-2-6, IEC 60068-2-64

      Safety
      EN 60950-1, IEC 60950-1, IEC 62368-1, UL 62368-1



    MTBF

      Time
      MGate MB3170/MB3170I Series: 1,349,710 hrs
      MGate MB3170-M-SC/M-ST/S-SC Series: 1,175,887 hrs
      MGate MB3170I-M-SC Series: 768,343 hrs
      MGate MB3170I-S-SC Series: 763,707 hrs
      MGate MB3270/MB3270I Series: 1,236,384 hrs

      Standards
      Telcordia SR332




Package Contents

    Device
      1 x MGate MB3170/MB3270 Series gateway

    Documentation
      1 x quick installation guide
      1 x warranty card



Ordering Information
Available Models
MGate MB3170: 1-port advanced Modbus gateway, 0 to 55°C operating temperature
MGate MB3170I: 1-port advanced Modbus gateway with 2 KV isolation, 0 to 55°C operating temperature
MGate MB3270: 2-port advanced Modbus gateway, 0 to 55°C operating temperature
MGate MB3270I: 2-port advanced Modbus gateway with 2 KV isolation, 0 to 55°C operating temperature
MGate MB3170-T: 1-port advanced Modbus gateway, -40 to 75°C operating temperature
MGate MB3170I-T: 1-port advanced Modbus gateway with 2 KV isolation, -40 to 75°C operating temperature
MGate MB3270-T: 2-port advanced Modbus gateway, -40 to 75°C operating temperature
MGate MB3270I-T: 2-port advanced Modbus gateway with 2 KV isolation, -40 to 75°C operating temperature
MGate MB3170-M-SC : 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (SC connectors), 0 to 60°C operating temperature
MGate MB3170-M-SC-T 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (SC connectors), -40 to 75°C operating temperature
MGate MB3170-M-ST 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (ST connectors), 0 to 60°C operating temperature
MGate MB3170-M-ST-T 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (ST connectors), -40 to 75°C operating temperatureD>
MGate MB3170-S-SC 1-port advanced Modbus gateway with 1 100BaseF(X) single-mode fiber port (SC connectors), 0 to 60°C operating temperature
MGate MB3170-S-SC-T 1-port advanced Modbus gateway with 1 100BaseF(X) single-mode fiber port (SC connectors), -40 to 75°C operating temperature
MGate MB3170I-M-SC 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical isolation, 0 to 60°C operating temperature
MGate MB3170I-M-SC-T 1-port advanced Modbus gateway with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical isolation, -40 to 75°C operating temperature
MGate MB3170I-S-SC 1-port advanced Modbus gateway with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical isolation, 0 to 60°C operating temperature
MGate MB3170I-S-SC-T 1-port advanced Modbus gateway with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical isolation, -40 to 75°C operating temperature
Optional Accessories (can be purchased separately)
CBL-F9M9-150 DB9 female to DB9 male serial cable, 1.5 m
CBL-F9M9-20 DB9 female to DB9 male serial cable, 20 cm
Mini DB9F-to-TB DB9 female to terminal block connector
CBL-PJTB-10 Non-locking barrel plug to bare-wire cable


Clients qui ont dájà consulté cet article ont également vu
Accepter

Ce site utilise des cookies pour offrir la meilleure expérience possible. Plus de détails.