MOXA CN2610 / CN2650 Series

SPHINX en Europe
FR
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Groupes de produits > Device Server > MOXA CN2610 / CN2650 Series

MOXA CN2610 / CN2650 Series

8 and 16-port RS-232/422/485 terminal servers with dual-LAN redundancy

MOXA CN2610 / CN2650 Series
2454_12130.png
2454_11748.jpg
2454_11749.jpg
2454_11750.jpg
2454_11751.png
2454_11752.png
2454_11753.png
2454_11754.png
  • Les caractéristiquesLes caractéristiques
  • PrésentationPrésentation
  • Plus d'informationPlus d'information
  • PDFPDF
  • LCD panel for easy IP address configuration
  • Dual-LAN cards with two independent MAC addresses and IP addresses
  • Redundant COM function available when both LANs are active
  • Dual-host redundancy can be used to add a backup PC to your system
  • Dual AC power inputs
  • Real COM/TTY drivers for Windows and Linux
  • Universal high-voltage range: 100 to 240 VAC or 88 to 300 VDC

Redundancy is an important issue for industrial networks, and various types of solutions have been developed to provide alternative network paths when equipment or software failures occur. “Watchdog” hardware is installed to utilize redundant hardware-and a “Token”- switching software mechanism is applied. The CN2600 terminal server uses its built-in Dual-LAN ports to implement a “Redundant COM” mode that keeps your applications running uninterrupted.

Dual-LAN Redundancy
The CN2600 has two separate LAN ports that can be connected to separate LAN networks. Dual-LAN redundancy involves setting up two separate physical networks to connect the PC host with the CN2600 (the PC host also requires two LAN cards). If one connection fails, the PC host can still communicate with your serial devices over the alternative LAN connection.

Redundant COM
Moxa offers “Redundant COM”, an easy-to-use application to provide an alternative solution for network redundancy. When the CN2600 receives a data packet from a connected device, two identical data packets are sent over two independent LAN connections to prevent lost data packets if one LAN connection becomes unavailable. The CN2600 software is programmed to automatically discard duplicate data packets.

Dual-host Redundancy
The CN2600’s dual LAN cards can also be used to set up “dual-host” redundancy. In this case, both networks (LAN A and LAN B in the figure) are connected to two different hosts. If either of the two hosts shuts down unexpectedly, the other host will still be able to communicate with serial devices connected to the CN2600.

Dual-AC Model Supported
Dual-power redundancy uses two power inputs and redundant internal power supplies to ensure that all of the CN2600’s functions will be available, even in the event of power circuit failures.

ProdGrafik
Ethernet Interface

Number of Ports
2 (2 IPs)

Speed
10/100 Mbps, auto MDI/MDIX

Connector
8-pin RJ45

Magnetic Isolation
1.5 kV built-in


Serial Interface

Number of Ports
8 or 16

Serial Standards
CN2610: RS-232
CN2650/2650I: RS-232/422/485

Connector
CN2610/2650: 8-pin RJ45
CN2650I: DB9 male

RS-485
Data Direction Control ADDC® (Automatic Data Direction Control)

Serial Line Protection
2 kV optical isolation (CN2650I)

Console Port
Dedicated RS-232 console port on rear panel (8-pin RJ45)


Serial Communication Parameters

Data Bits
5, 6, 7, 8

Stop Bits
1, 1.5, 2

Parity
None, Even, Odd, Space, Mark

Flow Control
RTS/CTS, DTR/DSR, XON/XOFF

Baudrate
50 bps to 921.6 kbps

Pull High/Low Resistor for RS-485
1 kÙ, 150 kÙ

Terminator for RS-485
120 Ù


Serial Signals

RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422
Tx+, Tx-, Rx+, Rx-, GND

RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w
Data+, Data-, GND


Software

Network Protocols
ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP, ARP, PPPoE, DDNS

Security Protocols
RADIUS, HTTPS, SSH, PAP, CHAP

Configuration Options
Web Console (exclude CN2610), Serial Console, Telnet Console, Windows Search Utility

Windows Real COM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1 (x86/x64),
Windows 2008 R2/2012/2012 R2 (x64),Windows Embedded CE 5.0/6.0, Windows XP Embedded

Fixed TTY Drivers
SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

Linux Real TTY Drivers
Linux 2.4.x, 2.6.x, 3.x

Management
SNMP MIB-II

IP Routing
Static, RIP-I, RIP-II


Operation Modes

Standard
Real COM, TCP Server, TCP Client, UDP, RFC2217, Terminal, Reverse Telnet, PPP, DRDAS, Redundant COM, Disabled


Applications

Terminal Sessions
8 sessions per port


Physical Characteristics

Housing
Metal

Weight
CN2610-8-2AC: 3760 g
CN2610-16-2AC: 3810 g
CN2650-8: 3740 g
CN2650-16: 3790 g
CN2650-8-2AC: 3900 g
CN2650-16-2AC: 3980 g
CN2650I-8: 3666 g
CN2650I-16: 3776 g
CN2650I-8-2AC: 3932 g
CN2650I-16-2AC: 4022 g
CN2650I-8-HV: 3910 g
CN2650I-16-HV: 3930 g

Dimensions
Without ears: 440 x 198 x 45.5 mm (17.32 x 7.80 x 1.77 in)
With ears: 480 x 198 x 45.5 mm (18.9 x 7.80 x 1.77 in)


Environmental Limits

Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)

Storage Temperature
Standard Models: -40 to 75°C (-40 to 167°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
High Voltage Wide Temp. Models: -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.


Power Requirements

Input Voltage
AC Models: 100 to 240 VAC, 47 to 63 Hz

DC Models:
110 VDC (88 to 300 VDC)

Power Consumption
CN2650 AC models: 235 mA @ 100 VAC, 145 mA @ 240 VAC
CN2650I HV models: 152 mA @ 88 VDC, 86 mA @ 300 VDC

Power Line Protection
1 kV burst (EN 61000-4-4: EFT/B), 2 kV surge (EN 61000-4-5)


Standards and Certifications

EMI
EN 55022 Class A, FCC part 15 Subpart B Class A

EMS
EN 61000-4-2 ESD: contact 4 kV; air 8 kV
EN 61000-4-3 RS: 3 V/m (80 MHz to 1 GHz)
EN 61000-4-4 EFT: Power 4 kV; Signal 2 kV
EN 61000-4-5 Surge: AC 1 kV (AC models); DC 2 kV (HV models); Signal 1 kV
EN 61000-4-6 CS: 3 V
EN 61000-4-8
EN 61000-4-11: AC m

Safety
UL 60950-1, EN 60950-1

EMC
55022/24

Freefall
IEC-68-2-34, IEC-68-2-32

Vibration
IEC-68-2-6

Green Product
RoHS, CRoHS, WEEE


Reliability

Alert Tools
Built-in buzzer and RTC (real-time clock)

Automatic Reboot Trigger
Built-in WDT (watchdog timer)

MTBF (mean time between failures)
CN2650I AC models: 99,320 hrs
CN2650I-8-HV-T: 191,326 hrs
CN2650I-16-HV-T: 116,924 hrs




Ordering Information


CN2610-8
    Dual-LAN terminal server with 8 RS-232 ports

CN2610-16
    Dual-LAN terminal server with 16 RS-232 ports

CN2610-8-2AC
    Dual-LAN, dual-AC-power terminal server with 8 RS-232 ports

CN2610-16-2AC
    Dual-LAN, dual-AC-power terminal server with 16 RS-232 ports

CN2650-8
    Dual-LAN terminal server with 8 RS-232/422/485 ports

CN2650-16
    Dual-LAN terminal server with 16 RS-232/422/485 ports

CN2650-8-2AC
    Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports

CN2650-16-2AC
    Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports

CN2650I-8
    Dual-LAN terminal server with 8 RS-232/422/485 ports and 2 KV optical isolation

CN2650I-16
    Dual-LAN terminal server with 16 RS-232/422/485 ports and 2 KV optical isolation

CN2650I-8-2AC
    Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports and 2 KV optical isolation

CN2650I-16-2AC
    Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports and 2 KV optical isolation

CN2650-8-2AC-T
    Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports, -40 to 75°C operating temperature

CN2650-16-2AC-T
    Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports, -40 to 75°C operating temperature

CN2650I-8-HV-T
    Dual-LAN terminal server with 8 RS-232/422/485 ports and 2 kV optical isolation, 88 to 300 VDC power input, -40 to 85°C operating temperature

CN2650I-16-HV-T
    Dual-LAN terminal server with 16 RS-232/422/485 ports and 2 kV optical isolation, 88 to 300 VDC power input, -40 to 85°C operating temperature

Clients qui ont dájà consulté cet article ont également vu
Accepter

Ce site utilise des cookies pour offrir la meilleure expérience possible. Plus de détails.